- A low-priced, very small-sized load cell dedicated to compression test.
- Most suitable for measurement in a limited space.
Example of use
- Useful for measurement of load distribution, etc. by use of several load cells.
Specifications
| CM Series | |
| Rated capacity | 10N~2kN |
| Rated output | Approx. 1 mV/V |
| Nonlinearity | 1%R.O. |
| Hysteresis | 1%R.O. |
| Repeatability | 0.3%R.O. |
| Recommended applied voltage | 6V |
| Allowable applied voltage | 10N~50N : 6V 100N~2kN : 10V |
| Input/output resistance | 350Ω±2% |
| Insulation resistance | 1000 MΩ or over |
| Temperature compensation range | -10~+70℃ |
| Allowable temperature range | -20~+80℃ |
| Zero point influence by temperature | ±0.05%R.O./℃ |
| Output influence by temperature | ±0.05%R.O./℃ |
| Allowable overload | 150%R.C. |
| Cable length | 3m |
| Tip shape | Y terminal |