Products

Load cell for compression test

Model CH Series

・Easy installation on pressing machines and jigs and low height to make this model most suitable for controlling press-fitting and caulking load.

Load cell for compression test-Model CH Series

Examples of use

Widely used for press-fitting and caulking.

Specifications

Model Model CH Series
Rated capacity 5kN - 500kN
Rated output 1mV/V±1%
Nonlinearity 0.5%R.O.
Hysteresis 0.5%R.O.
Repeatability 0.1%R.O.
Recommended applied voltage 10V
Allowable applied voltage 15V
Input/output resistance 700Ω±2%(5kN : 350Ω±2%)
Insulation resistance 2000 MΩ or over
Temperature compensation range -10 ~ +70°C
Allowable temperature range -20 ~ +80°C
Zero point influence by temperature ±0.01%R.O./°C
Output influence by temperature ±0.01%R.O./°C
Allowable overload 150%R.C.
Cable length 3m
Tip shape Y terminal

External View (PDF)