{"id":576,"date":"2018-11-07T14:13:13","date_gmt":"2018-11-07T05:13:13","guid":{"rendered":"http:\/\/www.aikoh.co.jp\/?p=576"},"modified":"2024-08-10T18:24:38","modified_gmt":"2024-08-10T09:24:38","slug":"cs","status":"publish","type":"post","link":"https:\/\/www.aikoh.co.jp\/en\/loadcell\/cs\/","title":{"rendered":"Load cell for compression test CS Series"},"content":{"rendered":"<ul>\n<li>A large-capacity and highly precise load cell for compression test.<\/li>\n<li>Highly resistant to the bending moment to make this model suitable for such tests as fatigue test and repeated load test of workpieces.<\/li>\n<\/ul>\n<h4 class=\"style4b\">Specifications<\/h4>\n<div class=\"s_table\"><table style=\"width: 625px\">\n<tbody>\n<tr>\n<td style=\"width: 297px\"><\/td>\n<td style=\"width: 265px\">CS\u00a0Series<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Rated capacity<\/td>\n<td style=\"width: 265px\">5kN\uff5e500kN<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Rated output<\/td>\n<td style=\"width: 265px\">2mV\/V\u00b10.25\uff05\uff0810kN : 1.5mV\/V\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Nonlinearity<\/td>\n<td style=\"width: 265px\">0.1\uff05R.O.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Hysteresis<\/td>\n<td style=\"width: 265px\">0.1\uff05R.O.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Repeatability<\/td>\n<td style=\"width: 265px\">0.05\uff05R.O.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Recommended applied voltage<\/td>\n<td style=\"width: 265px\">10V<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Allowable applied voltage<\/td>\n<td style=\"width: 265px\">15V<\/td>\n<\/tr>\n<tr>\n<td class=\"table_txt\" style=\"width: 297px\">Input\/output resistance<\/td>\n<td style=\"width: 265px\">350\u03a9\u00b12\uff05<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Insulation resistance<\/td>\n<td style=\"width: 265px\">1000 M\u03a9 or over\uff08DC50V\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Temperature compensation range<\/td>\n<td style=\"width: 265px\">-10\uff5e+70\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Allowable temperature range<\/td>\n<td style=\"width: 265px\">-20\uff5e+80\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Zero point influence by temperature<\/td>\n<td style=\"width: 265px\">\u00b10.005\uff05R.O.\/\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Output influence by temperature<\/td>\n<td style=\"width: 265px\">\u00b10.005\uff05R.O.\/\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Allowable overload<\/td>\n<td style=\"width: 265px\">150\uff05R.C.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Cable length<\/td>\n<td style=\"width: 265px\">3m<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 297px\">Tip shape<\/td>\n<td style=\"width: 265px\">Y terminal<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<h4 class=\"style4b\">Document download and related products<\/h4>\n<p><a class=\"q_button bt_red\" href=\"http:\/\/www.aikoh.co.jp\/wp-content\/uploads\/dim_cs.pdf\" target=\"_blank\" rel=\"noopener\">External View(PDF)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"A large-capacity and highly precise load cell for compression test. Highly resistant to the bending moment to make this model suitable for such tests as fatigue test and repeated load test of workpieces. Specifications CS\u00a0Series Rated capacity 5kN\uff5e500kN Rated output 2mV\/V\u00b10.25\uff05\uff0810kN : 1.5mV\/V\uff09 Nonlinearity 0.1\uff05R.O. Hysteresis 0.1\uff05R.O. Repeatability 0.05\uff05R.O. Recommended applied voltage 10V Allowable applied voltage 15V Input\/output resistance 350\u03a9\u00b12\uff05 Insulation resistance 1000 M\u03a9 or over\uff08DC50V\uff09 Temperature compensation range -10\uff5e+70\u2103 Allowable temperature range -20\uff5e+80\u2103 Zero point influence by temperature \u00b10.005\uff05R.O.\/\u2103 Output influence by temperature \u00b10.005\uff05R.O.\/\u2103 Allowable overload 150\uff05R.C. Cable length 3m Tip shape Y terminal Document download and related products External View(PDF)","protected":false},"author":2,"featured_media":1080,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[13,29],"tags":[],"class_list":["post-576","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-loadcell","category-compression"],"_links":{"self":[{"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/posts\/576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/comments?post=576"}],"version-history":[{"count":5,"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/posts\/576\/revisions"}],"predecessor-version":[{"id":2685,"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/posts\/576\/revisions\/2685"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/media\/1080"}],"wp:attachment":[{"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/media?parent=576"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/categories?post=576"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aikoh.co.jp\/en\/wp-json\/wp\/v2\/tags?post=576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}